Support for dynamic test in Ozone
Support for the execution of Dynamic Tests within the OzoneCheck Instrument


Standards the instrument complies with:   
ASTM D1149;   ISO 1431-1;    

 
The Ozone Dynamic Test Flexometer assesses the ozone exposure resistance of rubber products under dynamic loading. This laboratory tool supports measurement of dynamic strength on elastomeric materials in accordance with ISO 1431-1, ASTM D1149, and SAE J1401.

A 10-position specimen holder, insertable into the ozone chamber, allows testing of up to ten specimens in the same session at 3–30 cycles/min, improving throughput and comparability. The touch-screen interface sets oscillation count and frequency; the flexometer stops automatically at the programmed values for controlled, repeatable performance.

To match diverse measurement requirements, the instrument offers mechanical adjustment of clamp spacing (50 mm default) and moving clamp travel from 2.5 to 30 mm, equivalent to 5–60% on a 50 mm specimen per the standards. This ensures precise reproduction of specified conditions and reliable verification of resistance under representative dynamic exposure.

Support for dynamic test 
Device, in compliance with ISO 1431, ASTM D1149 and SAE J1401, to be inserted into test chamber for the study of ozone resistance of cured rubber under dynamic conditions (from 3 to 30 cycles/min - 0.05 to 0.5 Hz).
Up to 10 samples can be tested at the same time


Control Display 
The instrument's Touch-Screen Display allows you to set:
• The number of swings to be made
• The Oscillation frequency

The instrument will stop automatically when the set number of oscillations is reached




Adjustment of instrument displacement 
The instrument allows the mechanical adjustment of:
• the distance between the clamps for fixing or specimens (default 50 mm)
• the stroke performed by the mobile clamp: from 2.5 to 30 mm (between 5% and 60% for 50 mm specimen in accordance with the standards)


Insertion into the Test Chamber 
The Dynamic Tester is inserted into the test chamber using the motorized winch.
The same winch allows you to lift the device to check the condition of the specimens.

The lifting winch is controlled by the interlocked safety device which inhibits its operation if the ozone concentration inside the chamber is above the safety limits (10 pphm)



Number of Samples 
10 
Frequency 
3 to 30 cicles/min (0.05 to 0.5 Hz) 
Adjustment of Displacement 
2.5 to 30 mm (from 5% to 60% for standard 50 mm Sample) 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Support for the execution of Dynamic Tests within the OzoneCheck Instrument
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
Support
for dynamic test in
Ozone
ozone cabinet dynamic test: Ozon Kontrol Oonometresi. Ozonlanmış bir atmosferde dinamik testler için fleksometre.
Get a Quotation

Support for the execution of Dynamic Tests within the OzoneCheck Instrument

Applications

The Ozone Dynamic Test Flexometer assesses the ozone exposure resistance of rubber products under dynamic loading. This laboratory tool supports measurement of dynamic strength on elastomeric materials in accordance with ISO 1431-1, ASTM D1149, and SAE J1401.

A 10-position specimen holder, insertable into the ozone chamber, allows testing of up to ten specimens in the same session at 3–30 cycles/min, improving throughput and comparability. The touch-screen interface sets oscillation count and frequency; the flexometer stops automatically at the programmed values for controlled, repeatable performance.

To match diverse measurement requirements, the instrument offers mechanical adjustment of clamp spacing (50 mm default) and moving clamp travel from 2.5 to 30 mm, equivalent to 5–60% on a 50 mm specimen per the standards. This ensures precise reproduction of specified conditions and reliable verification of resistance under representative dynamic exposure.

Support for dynamic test 

Device, in compliance with ISO 1431, ASTM D1149 and SAE J1401, to be inserted into test chamber for the study of ozone resistance of cured rubber under dynamic conditions (from 3 to 30 cycles/min - 0.05 to 0.5 Hz).
Up to 10 samples can be tested at the same time

ozone cabinet dynamic test: OzoneCheck Ozon Ölçer: ISO 7326'ya göre kauçuk hortumların statik çekme testi için destek.
OzoneCheck Ozon Ölçer: ISO 7326'ya göre kauçuk hortumların statik çekme testi için destek.

Control Display 

The instrument's Touch-Screen Display allows you to set:
• The number of swings to be made
• The Oscillation frequency

The instrument will stop automatically when the set number of oscillations is reached

ozone cabinet dynamic test: Ozone-Check Ozon ölçer. Dinamik ozon testleri için fleksometre. Kontrol ekranı.
Ozone-Check Ozon ölçer. Dinamik ozon testleri için fleksometre. Kontrol ekranı.

Adjustment of instrument displacement 

The instrument allows the mechanical adjustment of:
• the distance between the clamps for fixing or specimens (default 50 mm)
• the stroke performed by the mobile clamp: from 2.5 to 30 mm (between 5% and 60% for 50 mm specimen in accordance with the standards)

ozone cabinet dynamic test: Ozone-Check Ozon Ölçer. Dinamik ozona maruz kalma testleri için fleksometre detayı. ozone cabinet dynamic test: Ozone-Check Ozon Ölçer. Dinamik ozona maruz kalma testleri için fleksometre detayı. ozone cabinet dynamic test: Ozone-Check Ozon Ölçer: Dinamik ozon testleri için fleksometre strokunu ayarlamak için Nonio. ozone cabinet dynamic test: OzoneCheck Ozon Ölçer: Numunelerin dinamik test standına monte edilmesi.
ozone cabinet dynamic test: Ozone-Check Ozon ölçer: dinamik testler için fleksometre detayı.
 

Insertion into the Test Chamber 

The Dynamic Tester is inserted into the test chamber using the motorized winch.
The same winch allows you to lift the device to check the condition of the specimens.

The lifting winch is controlled by the interlocked safety device which inhibits its operation if the ozone concentration inside the chamber is above the safety limits (10 pphm)

ozone cabinet dynamic test: Ozon-Kontrol Ozon ölçer. Ozon dinamik test fleksometresinin test odasının içine yerleştirilmesi.
Ozon-Kontrol Ozon ölçer. Ozon dinamik test fleksometresinin test odasının içine yerleştirilmesi.

Technical specification

Reference Standards
Standards the instrument complies with:  ASTM D1149; ISO 1431-1;  
Number of Samples  10  Frequency  3 to 30 cicles/min (0.05 to 0.5 Hz)  Adjustment of Displacement  2.5 to 30 mm (from 5% to 60% for standard 50 mm Sample) 
Download
General catalogue mail request

Ozone Check - UV
Vedi anche: ISO 1431 ve ASTM D1149'a göre test için Ozone-Check ozon ölçer. Cihazın tam görünümü.
See Also   >
Static Test in Traction
Vedi anche: Ozone-Check Ozon Ölçer. Statik ozon maruziyet testleri için gezegensel etki standı.
See Also   >
De Mattia Fatigue Check
Vedi anche: Ortam sıcaklığı testi için standart versiyonda De Mattia fleksometresi. Cihazın tam görünümü.
See Also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.