Standards the instrument complies with:   
ASTM D1149;   ISO 1431-1;    

 
The Ozone Dynamic Test Flexometer assesses the ozone exposure resistance of rubber products under dynamic loading. This laboratory tool supports measurement of dynamic strength on elastomeric materials in accordance with ISO 1431-1, ASTM D1149, and SAE J1401.

A 10-position specimen holder, insertable into the ozone chamber, allows testing of up to ten specimens in the same session at 3–30 cycles/min, improving throughput and comparability. The touch-screen interface sets oscillation count and frequency; the flexometer stops automatically at the programmed values for controlled, repeatable performance.

To match diverse measurement requirements, the instrument offers mechanical adjustment of clamp spacing (50 mm default) and moving clamp travel from 2.5 to 30 mm, equivalent to 5–60% on a 50 mm specimen per the standards. This ensures precise reproduction of specified conditions and reliable verification of resistance under representative dynamic exposure.

Support for dynamic test 
Device, in compliance with ISO 1431, ASTM D1149 and SAE J1401, to be inserted into test chamber for the study of ozone resistance of cured rubber under dynamic conditions (from 3 to 30 cycles/min - 0.05 to 0.5 Hz).
Up to 10 samples can be tested at the same time


Control Display 
The instrument's Touch-Screen Display allows you to set:
• The number of swings to be made
• The Oscillation frequency

The instrument will stop automatically when the set number of oscillations is reached




Adjustment of instrument displacement 
The instrument allows the mechanical adjustment of:
• the distance between the clamps for fixing or specimens (default 50 mm)
• the stroke performed by the mobile clamp: from 2.5 to 30 mm (between 5% and 60% for 50 mm specimen in accordance with the standards)


Insertion into the Test Chamber 
The Dynamic Tester is inserted into the test chamber using the motorized winch.
The same winch allows you to lift the device to check the condition of the specimens.

The lifting winch is controlled by the interlocked safety device which inhibits its operation if the ozone concentration inside the chamber is above the safety limits (10 pphm)



Number of Samples 
10 
Frequency 
3 to 30 cicles/min (0.05 to 0.5 Hz) 
Adjustment of Displacement 
2.5 to 30 mm (from 5% to 60% for standard 50 mm Sample) 


Gibitre Instruments
Via dell'industria, 18
Bergamo (Italy)
te. +39 035 461146
www.gibitre.it
info@gibitre.it

Copyright Gibitre Instruments
Support for the execution of Dynamic Tests within the OzoneCheck Instrument
Campi di applicazione  >  Prove su pneumatici  >  Rheocheck MD - Drive
Support
for dynamic test in
Ozone
ozone cabinet dynamic test: Ozone-Check 臭氧测试仪。用于在臭氧环境中进行动态测试的挠性计。
Get a Quotation


支持动态臭氧测试 - 支持在 OzoneCheck 工具中运行动态测试
10位样品架,用于根据ISO 1431-1、ASTM D1149和SAE J1401标准进行动态测试,可置于测试舱内进行动态条件下的抗压测试(3至30次/分钟)。

该设备的触摸屏显示器可设置:• 所需振荡次数• 振荡频率达到设定振荡次数后,测力计将自动停止

该仪器可进行机械调节:• 试样固定夹具间的距离(默认值为50毫米)• 移动夹具的行程:2.5至30毫米(根据标准,对于50毫米试样,行程范围为5%至60%)

Support for the execution of Dynamic Tests within the OzoneCheck Instrument

Applications

The Ozone Dynamic Test Flexometer assesses the ozone exposure resistance of rubber products under dynamic loading. This laboratory tool supports measurement of dynamic strength on elastomeric materials in accordance with ISO 1431-1, ASTM D1149, and SAE J1401.

A 10-position specimen holder, insertable into the ozone chamber, allows testing of up to ten specimens in the same session at 3–30 cycles/min, improving throughput and comparability. The touch-screen interface sets oscillation count and frequency; the flexometer stops automatically at the programmed values for controlled, repeatable performance.

To match diverse measurement requirements, the instrument offers mechanical adjustment of clamp spacing (50 mm default) and moving clamp travel from 2.5 to 30 mm, equivalent to 5–60% on a 50 mm specimen per the standards. This ensures precise reproduction of specified conditions and reliable verification of resistance under representative dynamic exposure.

Support for dynamic test 

Device, in compliance with ISO 1431, ASTM D1149 and SAE J1401, to be inserted into test chamber for the study of ozone resistance of cured rubber under dynamic conditions (from 3 to 30 cycles/min - 0.05 to 0.5 Hz).
Up to 10 samples can be tested at the same time

ozone cabinet dynamic test: OzoneCheck 臭氧测试仪:支持根据 ISO 7326 标准对橡胶软管进行静态拉伸测试。
OzoneCheck 臭氧测试仪:支持根据 ISO 7326 标准对橡胶软管进行静态拉伸测试。

Control Display 

The instrument's Touch-Screen Display allows you to set:
• The number of swings to be made
• The Oscillation frequency

The instrument will stop automatically when the set number of oscillations is reached

ozone cabinet dynamic test: Ozone-Check 臭氧测试仪。用于动态臭氧测试的柔性计。控制显示屏。
Ozone-Check 臭氧测试仪。用于动态臭氧测试的柔性计。控制显示屏。

Adjustment of instrument displacement 

The instrument allows the mechanical adjustment of:
• the distance between the clamps for fixing or specimens (default 50 mm)
• the stroke performed by the mobile clamp: from 2.5 to 30 mm (between 5% and 60% for 50 mm specimen in accordance with the standards)

ozone cabinet dynamic test: Ozone-Check 臭氧测试仪。用于动态臭氧暴露测试的挠性计细节。 ozone cabinet dynamic test: Ozone-Check 臭氧测试仪。用于动态臭氧暴露测试的挠性计细节。 ozone cabinet dynamic test: Ozone-Check 臭氧计:Nonio,用于调整动态臭氧测试的挠性计行程。 ozone cabinet dynamic test: OzoneCheck 臭氧测试仪:将试样安装在动态试验台上。
ozone cabinet dynamic test: Ozone-Check 臭氧测试仪:用于动态测试的挠性计细节。
 

Insertion into the Test Chamber 

The Dynamic Tester is inserted into the test chamber using the motorized winch.
The same winch allows you to lift the device to check the condition of the specimens.

The lifting winch is controlled by the interlocked safety device which inhibits its operation if the ozone concentration inside the chamber is above the safety limits (10 pphm)

ozone cabinet dynamic test: Ozone-Check 臭氧测试仪。将臭氧动态测试挠性规插入测试室。
Ozone-Check 臭氧测试仪。将臭氧动态测试挠性规插入测试室。

Technical specification

Reference Standards
Standards the instrument complies with:  ASTM D1149; ISO 1431-1;  
Number of Samples  10  Frequency  3 to 30 cicles/min (0.05 to 0.5 Hz)  Adjustment of Displacement  2.5 to 30 mm (from 5% to 60% for standard 50 mm Sample) 
Download
General catalogue mail request

Ozone Check - UV
Vedi anche: Ozone-Check 臭氧测试仪,用于根据 ISO 1431 和 ASTM D1149 标准进行测试。仪器全貌。
See Also   >
Static Test in Traction
Vedi anche: Ozone-Check 臭氧检测仪。用于静态臭氧暴露测试的行星效应支架。
See Also   >
De Mattia Fatigue Check
Vedi anche: De Mattia 挠性规标准型,用于环境温度测试。仪器全貌。
See Also   >
News
Call to action
Ask for quotation
a guided way to ask
for a quotation
Mail
info@gibitre.it
The good old e-mail
ready for every season
Phone
+39 035 460146
We welcome your calls Monday through Friday from 8:30 a.m. to 5:30 p.m. in your local time zone.
Newsletter
Subscribe
Stay updated
with the last news
of your sector
Local agent
from: -
See the whole list

In your country
in your language
at your service
Gibitre Instruments S.r.l., Via dell'industria 73, 24126 Bergamo Italia, pec@gibitre-instruments.it P. IVA: IT02827900164 CCIAA REA Bergamo: 326486 | ©2018 - 2026 Gibitre Instruments
Optimist.it
Welcome to the Gibitre Instruments web site
Please chose the preferred Cookie Management.
Benvenuti nel sito Gibitre Instruments
Per continuare scegliete la Gestione dei Cookie che preferite.
Cookies policy
For detailed informations about the use of cookies, please read our
Cookies Management Practice.

Gestione dei Cookies
Per maggiori informazioni sui cookie utilizzati consultate la nostra
Procedura sull'Uso dei Cookies.